BE1 Numerical Protection Systems
 

BE1 Numerical Protection Systems navigation


BE1 Numerical Protection Systems are available in rack mount or retrofit friendly packages for any application.

Click here to see communications capabilities for the entire line. Visit the Logic Library to view preconfigured logic schemes for BE1-11 relays.

Divider Line


BE1-11f
Feeder Protection System
 

Product Bulletin

Instruction Manual

Protocol Manuals

Product Software

Application Guides

Guideform Specifications and Drawings

Bulletin URH (includes stylechart)

BE1-11f Manual

DNP3 Manual

BESTCOMSPlus®

Generator Protection

MicrosoftWorddoc  BE1-11f Specs

 

Quick Start Guide

Modbus Manual

BEST61850™

Transformer Protection

AdobeReaderlogo BE1-11f Specs

 

 

IEC 61850 Manual

 

 

Product Drawings

Click here for Application Notes and other Resources

 

BE1-11f Feeder Protection System
Available in fully drawout
half rack case or in compact S1 size case

The BE1-11f is a complete distribution feeder protection system providing protection, control, monitoring and metering for industrial and utility feeders along with bus protection.

Protection features available include time and instantaneous overcurrent, overvoltage, undervoltage, directional power, frequency, synchronism check, reclosing, and RTD and analog I/O functions.

Standard features include:

  • Intuitive BESTCOMSPlus® and BESTlogic™Plus user interfaces with high-speed, front panel USB feature multiple customizable pre-designed templates.
  • Twenty-four industry standard timing curves, four custom table curves and one user-programmable curve provide flexibility to meet specific protection applications.
  • Each overcurrent element can be individually set for forward or reverse directional or non-directional control. Voltage control and restraint are included within the phase overcurrent elements to provide maximum functional flexibility for specific applications.
 
Protective Relays
Application Table
Application Engineers
Regional Sales Managers
Sales Reps
Next Page


Device Functions
 

  25 - Sync-Check 27 - Undervoltage 32 - Directional Power
       
  43 - Manual Transfer 47 - Phase Sequence 49RTD - RTD Monitoring
       
  50 - Instantaneous Overcurrent 51 - AC Time Overcurrent 59 - Overvoltage
       
  60 - Voltage Balance 62 - Time Delay 67 - AC Directional Overcurrent
       
  BF - Breaker Failure 79 - AC Reclosing 81 - Frequency Relay
       
  86 - Lockout Relay 101 - Virtual breaker control Sensitive Earth Fault Option
SEF Option
Ethernet Option
Modbus Option
DNP3 Option
IEC 61850 Option
BESTCOMSPlus Makes It Easy
See How to Verify Your Settings the EASY way
  • Sensitive earth fault protection available.
  • Includes distance to the fault to aid in timely fault location and service restoration.  Power quality reporting.
  • Real-time clock with 8-hour ride through and 5-year battery backup.
  • Large, high-contrast programmable 128x64 LCD display provides a menu tree with progress bars that make the front panel navigation intuitive.
  • Selectable protocols support integration with SCADA and distributed control systems.
  • Copper or fiber-optic Ethernet communications and RS-485 for BESTCOMSPlus®, BESTnet™Plus, Modbus™, DNP3 and BEST61850 protocols.
  • 10/100Mbit copper or 100Mbit fiber-optic Ethernet with IEC 61850.
  • Web page and user-selectable email triggers for remote alarm reporting.
  • Optional second set of CTs for primary feeder protection and backup adjacent feeder applications, or dual feeder protection for over and under switchgear feeder applications.
  • Optional Remote RTD module provides a choice of RTD types and analog input and output channels.
  • Optional enhanced HMI with user-customizable labels and virtual select and operate switches.
  • Available in fully drawout half-rack case in a rack mount or panel mount configuration, or in a non-drawout S1 sized case that fits in an S1 case opening.

Upgrade Option

Upgrade from the BE1-951 to the BE1-11f and get more protection, increased data capturing, more advanced logic, and enhanced communications. Use the style conversion chart to make it easy to determine the style you need.

Enhancement Accessories for the BE1-11f

Remote RTD ModuleBE1-11m RTD Module

Remote RTD Module provides up to 12 remote RTD inputs, 4 remote analog inputs, and 4 remote analog outputs for the BE1-11f. The Remote RTD Module communicates with the BE1-11f through either a RS-485 connection or copper Ethernet or an optional fiber Ethernet connection

Two Remote RTD Modules may be connected to a single BE1-11f Feeder Protection System for complete thermal condition monitoring and provide process control monitoring and display capabilities.

For more information, see Bulletin URH.

 

Application Notes and Technical Papers and other Resources

Application Notes
- Application Note PC-BESTSPACE - Use the BESTCOMSPlus® BESTspace™ feature to easily set your relay
- Application Note PC-BACKUPBUS - Preprogrammed Logic: Backup Bus Overcurrent Protection / Backup Bus Overcurrent Protection BESTspace file
- Application Note - PC-BASICLOGIC - Preprogrammed Logic Schemes: Basic Overcurrent Protection / Basic Overcurrent Protection BESTspace file
- Application Note PC-CONTROL - Preprogrammed Logic: Overcurrent Protection with Control / Overcurrent Protection with Control BESTSspace file
- Application Note PC-FEEDER - Preprogrammed Logic: Feeder Protection with Interlock / Feeder Protection with Interlock BESTspace file
- Application Note PC-PRIMARYBUS - Preprogrammed Logic: Primary Bus Overcurrent Protection / Primary Bus Overcurrent Protection BESTspace file
- Application Note - PC-RECLOSING - Preprogrammed Logic Schemes: Overcurrent Protection with Reclosing / Overcurrent Protection with Reclosing BESTspace file
- Application Note PC-IPS01 - An under frequency load shedding protection solution that meets NPCC regulatory change in the Northeast United States.
Technical Papers
- Using GOOSE Messages in a Main-Tie-Main Scheme
-
Protective Relaying Methods for Reducing Arc Flash Energy
- A Review of Negative Sequence Current
- Load Shedding for Utility and Industrial Power System Reliability
- Reliability Considerations of Multifunction Protection
- Myths of Protecting the Distributed Resource To Electric Power System Interconnection
- Distributive Generation and Interconnection: Protection, Monitoring, and Interconnection Opportunities
- Protective Relaying When Distributed Generation is Added to Your Circuit
- Intertie Requirements for DGs Connected to Radial Distribution Feeders
- Breaker Monitoring with Numerical Relay
- Commissioning Numerical Relays
- Effects of Distributed Generation on Utility Protection Schemes

Other Resources
- Using GOOSE Messages in a Main-Tie-Main Scheme
- A Review of Negative Sequence Current
- RS-485 Considerations
- Load Shedding for Utility and Industrial Power System Reliability