BE1-11 Protection System

Correctly configuring protection with confidence has never been easier than with the BE1-11. The BE1-11 Protection System is designed with many features to address issues with reliability arising from the complexity of programming. With BESTspace™ files, multiple BESTlogic™Plus preprogrammed logic schemes, and associated application notes, you can be confident that you have the protection you need. The BE1-11 is available in Feeder, Generator, Intertie, Transformer, and Motor styles for multiple applications.

Benefits

IEEE Device Functions
21 24 25 25A 27 32 37
40 43 46 47 48 49RTD 49TC
50 51 51TF 55 59 60 62
64G 66 67 76 78V 78OOS 79
81 82 86 87 87N 101 50BF

Note: IEEE device functions are configured through the BE1-11 style number.

  • Entering protection settings with confidence is easy with BESTCOMSPlus® software that provides intuitive settings with graphs, built-in error checking, and summary screens.
  • Complex protection schemes are easy to configure and understand with preprogrammed schemes, drag-and-drop logic, user labels, and notes provided by BESTlogic™Plus.
  • The Offline Simulator in BESTlogic™Plus helps identify and troubleshoot the logic without the expensive need for physical hardware.
  • Adaptable coordination for difficult applications is made possible by 24 industry-standard timing curves and five user-defined curves.
  • Meet your modern communications needs with 10/100Mbit copper or 100Mbit fiber-optic Ethernet with IEC 61850, DNP, or Modbus®.
  • Connection is easy, even when using multiple large wires, with large screw terminals for all terminations.
  • Get the information you need for system analysis with distance-to-fault, oscillography, demand metering, power quality, breaker monitoring, and other data provided by the BE1-11.
  • Easily navigate settings and metering with the intuitive Human Machine Interface (HMI) menu and large LCD display.
  • Fully configurable analog outputs can be used to drive analog meters. Easily assign trip points and scale them to reflect measured parameters.
  • Up to 14 combined alarm and trip temperature monitoring points are possible using an optional RTD module.
  • Reduce installation costs and improve reliability by mounting an optional RTD module near the point of measurement to minimize cable lengths.
  • UL Class 1, Div 2 rating allows the optional RTD module to be installed in harsh environments.